- 200V-240V Input, Metered-by-Outlet Sw 30A rack Power Distribution Unit.
- Input: NEMA L6-30P (5.0 kW).
- Output Receptacles: Twenty-One (21) C13 Outlets, and three (3) C19 Outlets.
- 0U Vertical ing PDU.
- Cord Length: 9.8inches.
Product Description
-------------------
APC AP8641 Rack PDU 2G/ Switched Plus/ Zero U/ 30A/ 208V Power
Distribution
From the Manufacturer
---------------------
Superior Equipment and Data Protection
--------------------------------------
Why buy APC by Schneider Electric?
----------------------------------
Over the years, APC by Schneider Electric has received hundreds
of awards worldwide - more than any other power protection
manufacturer. Such designations have recognized APC by Schneider
Electric for both its reliable solutions and its overall business
performance.
Rack PDU 2G, Metered by Outlet with Sw, ZeroU, 30A,
200/208V, (21) C13 & (3) C19
-----------------------------------------------------------------
Metered-by-outlet Rack PDUs provide real-time remote monitoring
of each individual outlet to empower IT professionals with the
necessary tools for advanced data center energy management.
APC by Schneider Electric Metered by Outlet with Sw Rack
Power Distribution Units (PDUs) enable advanced,
user-customizable power control and individual outlet power
metering. Remote outlet level controls allow power on/off
functionality for power recycling to reboot locked-up equipment
and to avoid unauthorized use of individual outlets. Power
sequencing delays allow users to define the order in which to
power up or down attached equipment. Avoid circuit overload
during power recovery and extend uptime of critical equipment by
prioritizing the load shedding. Current metering provides
real-time remote monitoring of connected loads. Switched Rack
PDUs include real power monitoring, a temperature/humidity sensor
port, and locking IEC receptacles.
User-defined alarms warn of potential circuit overloads before
critical IT failures occur. Users can access, configure, and
control Switched Rack PDUs through secure Web, SNMP, Command Line
Interface, or Telnet Interfaces which are complimented by
Schneider Electric's StruxureWare solution.
AP8641 Features
---------------
* Metering-by-Outlet capability: Individual outlet level power
metering provides a more granular view of the power distributed
to equipment within the enclosure. It also provides the ability
to analyze component power trends and perform capacity planning.
Metered-by-Outlet Rack PDU Features & Benefits Availability
Metering-by-Outlet capability Individual outlet level power
metering provides a more granular view of the power distributed
to equipment within the enclosure. It also provides the ability
to analyze component power trends and perform capacity planning.
Network Management Full-featured network management interfaces
that provide standards-based management via Web, SNMP, and
Telnet. Allows users to access, configure, and manage units from
remote locations to save valuable time. Associated with this
feature is the ability to quickly and easily upgrade the firmware
via network download to installed units for future product
enhancements. Remote Individual Outlet Control Remotely manage
outlets so users can turn outlets off that are not in use
(prevent overloads) or recycle power to locked-up equipment
(minimize costly downtime and avoid travel time to equipment).
Alarm Thresholds Define alarm thresholds in order to avoid
overloaded circuits. Network and visual alarms inform the user of
possible problems. (Note: Only available on units with the
current monitoring capabilities. Please see SKU specifications
for availability) Local Current Monitoring Display The aggregate
current draw per power distribution unit is displayed on the unit
via a digital display. The local digital display helps installers
avoid overloaded circuits by providing a visible warning when the
current draw is close to the maximum amperage draw of the strip.
(Available on designated SKUs only) Power Delays Allows users to
configure the sequence in which power is turned on or off for
each outlet. This helps avoid in-rushes at start-up, which can
cause overloaded circuits and dropped loads. Sequencing also
allows users to predetermine which piece of equipment is turned
on first so other equipment dependant on that unit will function
properly. Load Indicator LED Indicates overload and warning
conditions based on the user-defined alarm thresholds. Alerts
users of potential overloaded circuits. Flash Upgradeable Quickly
and easily upgrade firmware via network download for future
product enhancements. Eliminates the need to replace products
already installed in the field when new features are released.
(Note: Networked units only)
Technical Specifications Output Nominal Output Voltage 208V
Maximum Total Current Draw per Phase 30A Output Connections (21)
IEC 320 C13 (3) IEC 320 C19 Overload Protection Yes Input
Nominal Input Voltage 208V Input Frequency 50/60 Hz Regulatory
Derated Input Current (North America) 24A Input Connections NEMA
L6-30P Cord Length 3 meters Number of Power Cords 1 Acceptable
Input Voltage 200-240 VAC Maximum Line Current per phase 30A
Maximum Input Current per phase 30A Physical Net Weight 8.23 kg
Maximum Height 1829.00 mm Maxiumum Width 56.00 mm Maximum Depth
51.00 mm Shipping Weight 10.50 kg Shipping Height 2038.00 mm
Shipping Width 162.00 mm Shipping Depth 118.00 mm Color Black
Units per Pallet 42.00 Environmental Operating Environment -5 -
45 °C Operating Relative Humidity 5 - 95% Operating Elevation 0 -
3000 meters Storage Temperature -25 - 65 °C Storage Relative
Humidity 5 - 95% Storage Elevation 0 - 15,000 meters Conformance
Regulatory Approvals cUL Listed, FCC Part 15 Class A, ICES-003,
UL Listed, VCCI Class A Standard Warranty 2 years repair or
replace Sustainable Offer Status RoHS Compliant